Microplates Blood Groups ABO/RhD + Reverse Grouping

ABO/RhD blood grouping test with reverse grouping contains 8 or 12 groupings per microplate

DiaMed-MP Test A, B, AB, DVI-, Ctl/A1, A2, B

DiaMed-MP Test A, B, AB, DVI-, Ctl/A1, A2, B

DiaMed-MP Test A, B, AB, DVI-, ctl/A1, A2, B contains 12 groupings per microplate. Additional reagents (DiaCell-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 64370):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), AB: ES131 (ES-15)/ES-4, D: TH-28 (IgM)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 64370) 144 profiles 110071
3 x 10 mL (Id-n°: 45432) DiaCell-MP ABO 200 Tests Set of 3 vials A1, A2, B 109895
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180

DiaMed-MP Test A, B, DVI-, DVI+, Ctl/A1, A2, B

DiaMed-MP Test A, B, DVI-, DVI+, Ctl/A1, A2, B

DiaMed-MP Test A, B, DVI-, DVI+, ctl/A1, A2, B contains 12 groupings per microplate. Additional reagents (DiaCell-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 60400):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), D: TH-28 (IgM) D: MS-201/MS-26 (IgM/IgG)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 60400) 144 profiles 110074
3 x 10 mL (Id-n°: 45432) DiaCell-MP ABO 200 Tests Set of 3 vials A1, A2, B 109895
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180

DiaMed-MP Test A, B, AB, DVI-, DVI+, Ctl/A1, B

DiaMed-MP Test A, B, AB, DVI-, DVI+, Ctl/A1, B

DiaMed-MP Test A, B, AB, DVI-, DVI+, ctl/A1, B contains 12 groupings per microplate. Additional reagents (DiaCell-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 61470):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), AB: ES131 (ES-15)/ES-4,
D: TH-28 (IgM), D: MS-201/MS-26 (IgM/IgG)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 61470) 144 profiles 110075
2 x 10 mL (Id-n°: 45422) DiaCell-MP ABO 200 Tests Set of 2 vials A1, B 109897
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180

DiaMed-MP Test A, B, AB, DVI-, Ctl/A1, B, O

DiaMed-MP Test A, B, AB, DVI-, Ctl/A1, B, O

DiaMed-MP Test A, B, AB, DVI-, ctl/A1, B, O contains 12 groupings per microplate. Additional reagents (DiaCall-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 65570):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), AB: ES131 (ES-15)/ES-4 D: TH-28 (IgM)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 65570) 144 profiles 110077
3 x 10 mL (Id-n°: 45452) DiaCell-MP ABO 200 Tests Set of 3 vials A1, B, O 109898
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180

DiaMed-MP Test A, B, AB, DVI-, DVI+, Ctl/A1, A2, B, O

DiaMed-MP Test A, B, AB, DVI-, DVI+, Ctl/A1, A2, B, O

DiaMed-MP Test A, B, AB, DVI-, DVI+, ctl/A1, A2, B, O contains 8 groupings per microplate. Additional reagents (DiaCall-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 62380):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), AB: ES131 (ES-15)/ES-4
D: TH-28 (IgM), D: MS-201/MS-26 (IgM/IgG)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 62380) 96 profiles 110072
4 x 10 mL (Id-n°: 45442) DiaCell-MP ABO 200 Tests Set of 4 vials A1, A2, B, O 109896
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180

DiaMed-MP Test A, B, DVI-, DVI+, Ctl/A1, A2, B, O

DiaMed-MP Test A, B, DVI-, DVI+, Ctl/A1, A2, B, O

DiaMed-MP Test A, B, DVI-, DVI+, Ctl/A1, A2, B, O

DiaMed-MP Test A, B, DVI-, DVI+, ctl/A1, A2, B, O contains 8 groupings per microplate. Additional reagents (DiaCall-MP ABO, ID-Diluent 1) are required.

Microplate (Id-n°: 63390):
•Cell lines: A: Birma-1, B: LM306/686 (LB-2), D: TH-28 (IgM), D: MS-201/MS-26 (IgM/IgG)

Ordering information

Pkg. size Profiles or single test REF
1 x 12 (Id-n°: 63390) 96 profiles 110073
4 x 10 mL (Id-n°: 45442) DiaCell-MP ABO 200 Tests Set of 4 vials A1, A2, B, O 109896
2 x 100 mL (Id-n°: 05751) ID-Diluent 1 009160
1 x 500 mL (Id-n°: 05751) ID-Diluent 1 009180